Thru Beam
Thru beam photoelectric sensors available with wide range of housing designs/materials and sensing characteristics. Sensing ranges of up to 70 metres. Infrared light source. Highest level of excess gain in thru beam provides reliable sensing through contaminated environments.
-
SpaceMaster™
- Operation mode and max sensing range:
- Thru-beam: 1-15 m
- Cable or plug connection
- Sensitivity adjustment via control input
- Wide variety of housings
- Power and output indicator
- High voltage tolerance to hostile environments
- 10-30 V dc supply voltage
- 3 wire, NPN or PNP transistor output
- Test input
- UL325 approved series optionally available (see datasheet for SM 3000 U series in Downloads)
- Available with optional ATEX approval
(II 3 G Ex nA IIC T6 Gc and II 3D Ex tc IIIC T100 ºC Dc)
- Operation mode and max sensing range:
-
SpaceMaster™
- Operation mode and max sensing range:
- Thru beam: 1-10 m
- Cable or plug connection
- Sensitivity adjustment via control input
- Power and output indicator
- 10-30 V dc supply voltage
- 3 wire, NPN or PNP transistor output
- Narrow optical beam
- TUV approved as safety device (AOPD) for power operated doors and gates acc. EN12978
- Operation mode and max sensing range:
-
SpaceMaster™
- Operation mode and max sensing range:
- Thru-beam: 1-6 m
- Cable or plug connection
- Sensitivity adjustment via control input
- Wide variety of housings
- Power and output indicators
- High tolerance to hostile environments
- 10-32 V dc supply voltage
- 3 wire, NPN or PNP output or 4 wire, NPN/PNP opto isolated output
- 5 or 0,5 ms response time
- Low current consumption
- Test input
- Available with optional ATEX approval
(II 3 G Ex nA IIC T6 Gc and II 3D Ex tc IIIC T100 ºC Dc)
- Operation mode and max sensing range:
-
SpaceMaster™
- Operation mode and max sensing range:
- Thru-beam: 0-20 m
- Diffuse proximity: 0-1 m
- Retro reflective: 0-3 m
- Fibre: Dependent on the fibre optic
- Cable or Plug connection
- Sensitivity adjustment via potentiometer
- Switch selectable light or dark function
- Power and output indicators
- High tolerance to hostile environments
- 10-30 V dc supply voltage
- 4 wire, NPN/PNP transistor output or 4 wire, ambivalent PNP/PNP transistor output
- Test input
- Operation mode and max sensing range:
-
SpaceMaster™
- Operation mode and max sensing range:
- Thru-beam: 0-20 m
- Diffuse proximity: 0-1 m
- Retro reflective: 0,1-3 m
- Fibre: Dependent on the fibre optic
- IO-Link communication interface
- IO-Link PC software for parameter configuration and diagnostics
- M8 or M12 plug connection
- Sensitivity adjustment via potentiometer
- Switch selectable light or dark function
- Power and output indicators
- High tolerance to hostile environments
- 10-30 V dc supply voltage
- 4 pin, IO-Link / push-pull and NPN or PNP output
- Test input
- Operation mode and max sensing range:
-
SpaceMaster™
- Operation mode and max sensing range:
- Thru-beam: 0-20 m
- Diffuse proximity: 0-1 m
- Retro reflective: 0-3 m
- Fibre: Dependent on fibre optic
- Cable or plug connection
- Sensitivity adjustment via potentiometer
- Switch selectable light or dark function
- Power and output indicators
- High tolerance to hostile environments
- 10-30 V dc or 20-250 V ac supply voltage
- 3 wire, NPN or PNP transistor output or 2 wire, SCR output
- Test input
- Available with optional ATEX approval
(II 3 G Ex nA IIC T6 Gc and II 3D Ex tc IIIC T100 ºC Dc)
- Operation mode and max sensing range:
-
SpaceMaster™
- Operation mode and max range:
- Thru-beam: 0-70 m
- Cable or plug connection
- Sensitivity adjustment via control input
- Power and output indicators
- High tolerance to hostile environments
- 10-30 V dc supply voltage
- Available outputs:
- NPN transistor output
- PNP transistor output
- Solid state output
- Test input
- High excess gain
- IP 69K rating
- Optical cross talk elimination of 4 independent sensor channels selectable via wire connection
- Available with optional ATEX approval
(II 3 G Ex nA IIC T6 Gc and II 3D Ex tc IIIC T100 ºC Dc) or
UL Hazloc compliant (Class II, Division 2, Groups F and G)
- Operation mode and max range:
-
SpaceMaster™
- Operation mode and max sensing range:
- Thru-beam: 0-70 m
- IO-Link communication interface
- PC software for parameter configuration and
diagnostics with optional USB-IO-Link Master 02 - M12 plug connection
- Transmitting power adjustment
- Power and output indicators
- High tolerance to hostile environments
- 10-30 V dc supply voltage
- 5 pin, IO-Link / push-pull and NPN or PNP output
- Test input
- High excess gain
- IP 69K rating
- Optical cross talk elimination of 4 independent
sensor channels selectable via IO-Link
- Operation mode and max sensing range:
-
SpacePak™
- Operation mode and max sensing range:
- Thru-beam: 0-45 m
- Diffuse proximity: 0-5 m
- Retro reflective: 0-12 m
- Polarised retro reflective: 0-10 m
- Background suppression: 0-2 m
- Compact rectangular housing (50 x 50 mm)
- Cable or rotatable plug connection
- Sensitivity adjustment via potentiometer
- Switch selectable light or dark function
- Adjustable on/off time delay
- Power, output and signal level indicators
- 10-30 V dc or 12-240 V ac/dc supply voltage
- 4 wire, NPN/PNP transistor output or 5 wire relay output
- Operation mode and max sensing range:
Quick Search
Or
Product Finder
Find the Telco product type you're looking for with the help of criteria search filters in the Telco product finder
Contact Us