Results 0 items
Enter your search criteria
SpaceGuard™ SERIES
Self-Contained Light Curtains
Light Curtains
Operation Mode | Thru Beam |
Function | Transmitter |
Supply Voltage | 10 - 30 V dc |
Active Height | 2340 mm |
Number of Channels | 23 |
Sensing Range | 12 m |
Housing | 12 mm x 14 mm |
Length | 2510 mm |
Connection | 0.3 m cable with 4 pin, M8 plug + 15 m ext. cable |
Operation Mode | Thru Beam |
Function | Receiver |
Supply Voltage | 10 - 30 V dc |
Active Height | 2340 mm |
Number of Channels | 23 |
Sensing Range | 12 m |
Output | 900 Hz 5 V square signal, OSE |
Response | 40 ms |
Housing | 12 mm x 14 mm |
Length | 2510 mm |
Connection | 0.3 m cable with 4 pin, M8 plug + 5 m ext. cable |
Features | Dynamic Sequential Blanking Function. Static Blanking Function. |
Max. Sequencial Blanking Speed | 1,6 m/s |
Supply Voltage | 10 - 30 V dc |
Reverse Polarity Protected | Yes |
Short Circuit Protected | Yes |
Current Consumption | 35 mA |
Power On Indicator | Green LED |
Output Indicator | Yellow LED |
System Status Indicator | Red LED |
Light Source | - |
Profile Dimensions (w x d) | U Profile, 12 mm x 14 mm |
Housing Material, Profile | Aluminium (black anodised) |
Cable | 4 x 0,20 mm² |
Cable Sleeve | PVC Ø 4,5 mm |
Channel spacing (Ch 1 excluded) | 45 mm: up to 540 mm 180 mm: from 540 mm to top |
Bottom spacing to Ch 1 | 35 mm |
Spacing between Ch 1 and Ch 2 | 10 mm |
Housing Material, Front cover (optional) | Polycarbonate |
Safety Category | EN 12978:2003 - EN 13849-1, Cat. 2, PL d - IEC 61496-2, Type 2 ESPE |
Tested | EN 12978:2003 +A1:2009. EN ISO 13849-1:2008. EN 61508:2010 Parts 1-7. IEC 61000-6-2:2005. EN 61000-6-3:2007 +A1:2011. IEC 61326-3-1:2008. |
Operation Temperature | – 20 to +55 °C |
Storage Temperature | – 40 to +80 °C |
Sealing Class | IP 67 |
Light Immunity 5˚ | > 100 000 lux |
Enter your search criteria
Or
Find the Telco product type you're looking for with the help of criteria search filters in the Telco product finder